Difference between revisions of "PH Loop"

From Chemical Engineering @ UP wiki
Jump to: navigation, search
m (Documentation)
(Added the documentation to the wiki)
Line 16: Line 16:
 
[http://ragnarok.up.ac.za/Rigs/02_pH/2007/pH_Control_CWSteyn.pdf Report] | [http://ragnarok.up.ac.za/Rigs/02_pH/2007/ Project files]
 
[http://ragnarok.up.ac.za/Rigs/02_pH/2007/pH_Control_CWSteyn.pdf Report] | [http://ragnarok.up.ac.za/Rigs/02_pH/2007/ Project files]
 
=== 2009 (Current) ===
 
=== 2009 (Current) ===
A.H. Campher, project to determine methods of obtaining the attainable- and desired output spaces (AOS and DOS) from a process model.<br/>
+
A.H. Campher, '''Maintenance, Modelling and Control of the pH-control Rig'''<br/>
[Report] | [Project files]
+
[http://ragnarok.up.ac.za/Rigs/02_pH/2009/CML732_Report_AH_Campher_2009.pdf Report] | [http://ragnarok.up.ac.za/Rigs/02_pH/2009/ Project files]
 
== Documentation ==
 
== Documentation ==
 
Large scale renaming of instruments, valves and tanks is being done. This renders all previous rig diagrams obsolete. Only 2009-updated diagrams should henceforth be used.
 
Large scale renaming of instruments, valves and tanks is being done. This renders all previous rig diagrams obsolete. Only 2009-updated diagrams should henceforth be used.
=== Process Flow diagrams ===
 
 
=== Piping & Instrumentation diagrams ===
 
=== Piping & Instrumentation diagrams ===
 +
[http://ragnarok.up.ac.za/Rigs/02_pH/02pH_P&ID_2009.vsd .VSD (Visio)] | [http://ragnarok.up.ac.za/Rigs/02_pH/02pH_P&ID_2009.pdf .PDF]
 
=== Wiring diagrams ===
 
=== Wiring diagrams ===
 +
[http://ragnarok.up.ac.za/Rigs/02_pH/02pH_WiringDiagram_2009.vsd .VSD (Visio)] | [http://ragnarok.up.ac.za/Rigs/02_pH/02pH_WiringDiagram_2009.pdf .PDF]
  
 
== Rig maintenance ==
 
== Rig maintenance ==
 
The maintenance of the pH rig is documented [[PH Rig Maintenance|here]].
 
The maintenance of the pH rig is documented [[PH Rig Maintenance|here]].

Revision as of 13:35, 16 November 2009

The pH control rig

PH control is a difficult problem due to the highly non-linear nature of the system. The steep slope of the titration curve around the pH = 7 point amplifies pH variations for even small base/acid addition variations. The pH control rig in the PMC lab illustrates that pH control is by no means impossible (albeit on a laboratory scale).

Current/Previous projects

1999

F.J. Botha, Ondersoek van die Dinamiese Gedrag van Sisteme waar pH Gemeet en Beheer word {Investigation of the Dynamic Behaviour of Systems where pH is Measured and Controlled}
[Hard copy of report available in pH rig folder]

2003

T. Leeuw & G. Mascini, pH Rig 2003 - CPL780 Process Control Laboratory
Report | Project files

2005

A.J. Swanepoel & M. Swanepoel (Botha), Model Based Control Laboratory, pH Control
Report | Project files

2007

C. Steyn, Fuzzy Logic Rule-Based Controller Design, Neutralization of Strong Acid with Strong Base
Report | Project files

2009 (Current)

A.H. Campher, Maintenance, Modelling and Control of the pH-control Rig
Report | Project files

Documentation

Large scale renaming of instruments, valves and tanks is being done. This renders all previous rig diagrams obsolete. Only 2009-updated diagrams should henceforth be used.

Piping & Instrumentation diagrams

.VSD (Visio) | .PDF

Wiring diagrams

.VSD (Visio) | .PDF

Rig maintenance

The maintenance of the pH rig is documented here.