Difference between revisions of "Big distillation column"

From Chemical Engineering @ UP wiki
Jump to: navigation, search
(Diagram)
Line 11: Line 11:
 
==Operator interface==
 
==Operator interface==
 
[[Image:gui.png|center|1000px]]
 
[[Image:gui.png|center|1000px]]
 +
 +
==Recent projects==
 +
  
 
==Contact persons==
 
==Contact persons==
Line 37: Line 40:
 
E-mail : Andre.Joubert@sasol.com
 
E-mail : Andre.Joubert@sasol.com
  
==Previous project documentation==  
+
==Documentation==  
 
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].
 
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].
  
==Help documentation==  
+
==Help==  
  
 
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].
 
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].

Revision as of 13:41, 17 November 2018

Description

The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.

Diagram

Column diagram.jpg

Control system

The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.

Operator interface

Gui.png

Recent projects

Contact persons

For help with the Emerson control system (Delta V) the contact person as of 2018-12 is:

Name: Daniela Straulino

Company: Avenge ACS

Tel: +27-11-249-6700

Cell: +27-82-407-8590

E-mail: Daniela.Straulino@avenggroup.com


For other general maintenance concerns and instrumentation problems the contact person is:

Name: Andre Joubert

Company: SASOL

Cell : +27-82-905-0090

E-mail : Andre.Joubert@sasol.com

Documentation

Documentation on past projects that were done on the distillation column can be found here.

Help

For help on the Delta V system and click here.