+ | ==Description== | ||
+ | The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the primary function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on | ||
+ | each stages. The Each plate is fitted with an RDT (resistance temperature detector) temperature | ||
+ | measurement device. Column instrumentation also includes various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. | ||
==Contact people== | ==Contact people== | ||
Line 5: | Line 9: | ||
Name: Daniela Straulino | Name: Daniela Straulino | ||
− | Company: | + | Company: [http://www.aveng-acs.com/ link Avenge ACS] |
Tel: +27-11-249-6700 | Tel: +27-11-249-6700 | ||
Line 25: | Line 29: | ||
==Documentation on previous projects== | ==Documentation on previous projects== | ||
− | |||
− | |||
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here]. | Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here]. | ||
Revision as of 12:07, 17 November 2018
Description
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the primary function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on each stages. The Each plate is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation also includes various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column.
Contact people
For help with the Emerson control system (Delta V) the contact person as of 2018-12 is:
Name: Daniela Straulino
Company: link Avenge ACS
Tel: +27-11-249-6700
Cell: +27-82-407-8590
E-mail: Daniela.Straulino@avenggroup.com
For other general maintenance concerns and instrumentation problems the contact person is:
Name: Andre Joubert
Company: SASOL (https://www.sasol.com/)
Cell : +27-82-905-0090
E-mail : Andre.Joubert@sasol.com
Documentation on previous projects
Documentation on past projects that were done on the distillation column can be found here.
Help documentation
Help on the Delta V system and how to use click here.