Olympus BH Microscope
+
Carl Zeiss Axio A1-Scope with Axiocam ERc 5S Microscope and Camera
 
+
 
Used to:  
 
Used to:  
 
#Measure wear scar and/or wear track size
 
#Measure wear scar and/or wear track size
Line 13: Line 12:
 
[[File:IMG 4455.JPG|400px|Right|thumb|BOCLE(Left) & SL-BOCLE(Right)]]   
 
[[File:IMG 4455.JPG|400px|Right|thumb|BOCLE(Left) & SL-BOCLE(Right)]]   
  
Both the Ball On Cylinder Lybricity Evaluator (BOCLE) and the Scuffing Load - Ball On Cylinder
+
The microscope is used to capture an image of a contact surface after a lubricity test was performed. The surface appearance of the wear scar can the n berated and the wear scar measured.  The microscope is equipped with three lenses that are used to obtain different enlargements of the imageThese include a 5x-, 10x- and 20x zoom.
Lubricity Evaluator work on the principle of testing the lubricity of a fuel/lubricant. A non-rotating
+
ball is forced against a rotating cylinder. The cylinder is partially immersed in a bath of the fuel to 
+
allow the fuel to be constantly carried to the area of contact.   
+
  
The BOCLE & SL-BOCLE machines operate on much the same principals. They are nearly identically
+
[File:IMG 4440.JPG|400px|right|thumb|Ball,Ring & Bath]]
constructed. They differ in:<br/>
+
1) The types of fuels they typically test.<br/>
+
2) The qualifying parameters and test methods (See ASTM link below).<br/>
+
3) The maximum load they can carry.<br/>
+
<br/>
+
 
+
The BOCLE is a wear test. A microscope and camera is used to quatify the size and record the appearance.
+
 
+
The SL-BOCLE is a load carrying capacity test. A series of loads are applied until a sudden
+
change in the friction coefficient is observed (higher than 0.175). This load then represents
+
some of the lubricity behaviour.<br/>
+
Note the suggested loading sequence in the operating manual.
+
 
+
[[File:IMG 4440.JPG|400px|right|thumb|Ball,Ring & Bath]]
+
  
  
Line 76: Line 58:
 
[ftp://ragnarok.up.ac.za/publicftp/lab/Tribology/New%20Folder/SLBOCLE%20wiring22012.vsd VISIO]<br/>
 
[ftp://ragnarok.up.ac.za/publicftp/lab/Tribology/New%20Folder/SLBOCLE%20wiring22012.vsd VISIO]<br/>
  
 
Piping diagram (Air flow)
 
Identical for both
 
[ftp://ragnarok.up.ac.za/publicftp/lab/Tribology/New%20Folder/BOCLE%20piping%20diagram.pdf click here]
 
  
 
== History of this Equipment ==
 
== History of this Equipment ==
The equipment was recieved from Sasol in 2012 after being used there for a period of time.
+
The microscope was recieved in 2013.
The equipment was conntected to the OPTO 22 network in 2012 by Jacques Langenhoven to allow data
+
logging and control through the lab network and OPTO system.
+
  
 
== Current/Previous projects ==
 
== Current/Previous projects ==

Revision as of 15:09, 28 June 2013

Carl Zeiss Axio A1-Scope with Axiocam ERc 5S Microscope and Camera Used to:

  1. Measure wear scar and/or wear track size
  2. Capture wear scar and/or wear track appearance.


Typically used with:

  1. BOCLE
  2. SL-BOCLE
  3. HFRR
  4. SRV
BOCLE(Left) & SL-BOCLE(Right)

The microscope is used to capture an image of a contact surface after a lubricity test was performed. The surface appearance of the wear scar can the n berated and the wear scar measured. The microscope is equipped with three lenses that are used to obtain different enlargements of the image. These include a 5x-, 10x- and 20x zoom.

[File:IMG 4440.JPG|400px|right|thumb|Ball,Ring & Bath]]


In this Table some basic differences are presented:


BOCLE table 2.jpg

Both units are operated via a simulink interfaces found on the PC next to the units (Univ PC nr: 766118).



Documentation

User Manual

A single user manual exists for both machines. click here

ASTM Standards

BOCLE (ASTM D5001) click here
SL-BOCLE (ASTM D6078) click here

Wiring, Flow & Instrumentation diagrams

Overall wiring diagram
BOCLE
PDF VISIO
SL-BOCLE
PDF VISIO


Detailed Opto wiring diagram
BOCLE
PDF VISIO
SL-BOCLE
PDF VISIO


History of this Equipment

The microscope was recieved in 2013.

Current/Previous projects

2012

Jacques Langenhoven, The commissioning of the BOCLE & SL-BOCLE in the Tribology lab
PDF
MS WORD