<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>http://chemeng.up.ac.za/wiki/index.php?action=history&amp;feed=atom&amp;title=PH_Rig_Maintenance</id>
		<title>PH Rig Maintenance - Revision history</title>
		<link rel="self" type="application/atom+xml" href="http://chemeng.up.ac.za/wiki/index.php?action=history&amp;feed=atom&amp;title=PH_Rig_Maintenance"/>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;action=history"/>
		<updated>2026-06-28T20:04:37Z</updated>
		<subtitle>Revision history for this page on the wiki</subtitle>
		<generator>MediaWiki 1.25.1</generator>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=1163&amp;oldid=prev</id>
		<title>28029187: /* 2011 */</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=1163&amp;oldid=prev"/>
				<updated>2011-11-28T14:53:26Z</updated>
		
		<summary type="html">&lt;p&gt;‎&lt;span dir=&quot;auto&quot;&gt;&lt;span class=&quot;autocomment&quot;&gt;2011&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;table class='diff diff-contentalign-left'&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;tr style='vertical-align: top;'&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;Revision as of 14:53, 28 November 2011&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;L40&quot; &gt;Line 40:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 40:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''Increase in Reagent storage capacity '''&amp;lt;br/&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''Increase in Reagent storage capacity '''&amp;lt;br/&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Two 100 l tanks were added to the system to increase the reagent storage capacity. The tanks were originally found &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Two 100 l tanks were added to the system to increase the reagent storage capacity. The tanks were originally found &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;to have leaks and were not fitted with manual valves. The leaks were repaired using epoxy and manual valves were fitted&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;to have leaks and were not fitted with manual valves. The leaks were repaired using epoxy and manual valves were fitted.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;to the tanks&lt;/del&gt;. The pH rig can now be operated continuously for over two hours.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The pH rig can now be operated continuously for over two hours.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>28029187</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=1162&amp;oldid=prev</id>
		<title>28029187 at 14:52, 28 November 2011</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=1162&amp;oldid=prev"/>
				<updated>2011-11-28T14:52:28Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class='diff diff-contentalign-left'&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;tr style='vertical-align: top;'&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;Revision as of 14:52, 28 November 2011&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;L36&quot; &gt;Line 36:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 36:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The Experion system should be run in parallel with any other control systems.&amp;#160; Access to OPTO can be set up through the OPTO Opc Server.&amp;#160; A graphical representation of the proposed control system can be seen [http://ragnarok.up.ac.za/publicftp/lab/Rigs/02_pH/2010/ here].&amp;#160; &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The Experion system should be run in parallel with any other control systems.&amp;#160; Access to OPTO can be set up through the OPTO Opc Server.&amp;#160; A graphical representation of the proposed control system can be seen [http://ragnarok.up.ac.za/publicftp/lab/Rigs/02_pH/2010/ here].&amp;#160; &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* A sample setup for the OPTO Opc server can be found [http://ragnarok.up.ac.za/publicftp/lab/Rigs/02_pH/2010/ here].&amp;#160; This includes the setup for the pH and level and flow rigs.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* A sample setup for the OPTO Opc server can be found [http://ragnarok.up.ac.za/publicftp/lab/Rigs/02_pH/2010/ here].&amp;#160; This includes the setup for the pH and level and flow rigs.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;== 2011 ==&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;'''Increase in Reagent storage capacity '''&amp;lt;br/&amp;gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Two 100 l tanks were added to the system to increase the reagent storage capacity. The tanks were originally found &lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;to have leaks and were not fitted with manual valves. The leaks were repaired using epoxy and manual valves were fitted&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;to the tanks. The pH rig can now be operated continuously for over two hours.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>28029187</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=956&amp;oldid=prev</id>
		<title>137.215.116.248: /* 2010 */</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=956&amp;oldid=prev"/>
				<updated>2010-11-10T10:44:12Z</updated>
		
		<summary type="html">&lt;p&gt;‎&lt;span dir=&quot;auto&quot;&gt;&lt;span class=&quot;autocomment&quot;&gt;2010&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;table class='diff diff-contentalign-left'&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;tr style='vertical-align: top;'&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;Revision as of 10:44, 10 November 2010&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;L34&quot; &gt;Line 34:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 34:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The pH rig computer was formatted and reinstalled with Windows 2003 Server. The license being used is a valid UP site license and should be preserved for future use.&amp;#160; It will have to be extracted from the running system first.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The pH rig computer was formatted and reinstalled with Windows 2003 Server. The license being used is a valid UP site license and should be preserved for future use.&amp;#160; It will have to be extracted from the running system first.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Honeywell Experion was then installed on the system and set up by Honeywell engineers.&amp;#160; The system ran for a while but the authentication went haywire before it could be fully set up.&amp;#160; At the moment it looks like the only possibility of recovery is a full format and reinstall.&amp;#160; The Experion license was changed during the install and the new license should be obtained from Devon Clack at honeywell if possible.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Honeywell Experion was then installed on the system and set up by Honeywell engineers.&amp;#160; The system ran for a while but the authentication went haywire before it could be fully set up.&amp;#160; At the moment it looks like the only possibility of recovery is a full format and reinstall.&amp;#160; The Experion license was changed during the install and the new license should be obtained from Devon Clack at honeywell if possible.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The Experion system should be run in parallel with any other control systems.&amp;#160; Access to OPTO can be set up through the OPTO Opc Server.&amp;#160; A graphical representation of the proposed control system can be seen here.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The Experion system should be run in parallel with any other control systems.&amp;#160; Access to OPTO can be set up through the OPTO Opc Server.&amp;#160; A graphical representation of the proposed control system can be seen &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;[http://ragnarok.up.ac.za/publicftp/lab/Rigs/02_pH/2010/ &lt;/ins&gt;here&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;]&lt;/ins&gt;. &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt; &lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* A sample setup for the OPTO Opc server can be found here.&amp;#160; This includes the setup for the pH and level and flow rigs.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* A sample setup for the OPTO Opc server can be found &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;[http://ragnarok.up.ac.za/publicftp/lab/Rigs/02_pH/2010/ &lt;/ins&gt;here&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;]&lt;/ins&gt;.&amp;#160; This includes the setup for the pH and level and flow rigs.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>137.215.116.248</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=955&amp;oldid=prev</id>
		<title>137.215.116.248: /* 2010 */</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=955&amp;oldid=prev"/>
				<updated>2010-11-10T10:39:55Z</updated>
		
		<summary type="html">&lt;p&gt;‎&lt;span dir=&quot;auto&quot;&gt;&lt;span class=&quot;autocomment&quot;&gt;2010&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;table class='diff diff-contentalign-left'&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;tr style='vertical-align: top;'&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;Revision as of 10:39, 10 November 2010&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;L32&quot; &gt;Line 32:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 32:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The waste drum setup was changed to accomodate two drums.&amp;#160; It is recommended that a y-fitting be inserted to the waste pipe so that both tanks fill up at the same time.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The waste drum setup was changed to accomodate two drums.&amp;#160; It is recommended that a y-fitting be inserted to the waste pipe so that both tanks fill up at the same time.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''Systems'''&amp;lt;br/&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''Systems'''&amp;lt;br/&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The pH rig computer was formatted and reinstalled with Windows 2003 Server&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The pH rig computer was formatted and reinstalled with Windows 2003 Server&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;. The license being used is a valid UP site license and should be preserved for future use.&amp;#160; It will have to be extracted from the running system first.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;* Honeywell Experion was then installed on the system and set up by Honeywell engineers.&amp;#160; The system ran for a while but the authentication went haywire before it could be fully set up.&amp;#160; At the moment it looks like the only possibility of recovery is a full format and reinstall.&amp;#160; The Experion license was changed during the install and the new license should be obtained from Devon Clack at honeywell if possible.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;* The Experion system should be run in parallel with any other control systems.&amp;#160; Access to OPTO can be set up through the OPTO Opc Server.&amp;#160; A graphical representation of the proposed control system can be seen here.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;* A sample setup for the OPTO Opc server can be found here.&amp;#160; This includes the setup for the pH and level and flow rigs.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>137.215.116.248</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=954&amp;oldid=prev</id>
		<title>137.215.116.248 at 10:33, 10 November 2010</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=954&amp;oldid=prev"/>
				<updated>2010-11-10T10:33:31Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class='diff diff-contentalign-left'&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;tr style='vertical-align: top;'&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;Revision as of 10:33, 10 November 2010&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;L23&quot; &gt;Line 23:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Fitting of stirrers to tanks found to be flimsy. Versatility of stands (moving them around) outweighed effort to construct new stands. Left as is, but sturdier stands are recommended.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Fitting of stirrers to tanks found to be flimsy. Versatility of stands (moving them around) outweighed effort to construct new stands. Left as is, but sturdier stands are recommended.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Rerouted pipe connecting CV001 and FE001 - cut away some of the metal structure to remove strain from pipe.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Rerouted pipe connecting CV001 and FE001 - cut away some of the metal structure to remove strain from pipe.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;== 2010 ==&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;'''Wiring/Instrumentation'''&amp;lt;br/&amp;gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;* Several attempts were made to get the Burkert Flow meter running but there is something wrong with the power supply.&amp;#160; It is recommended that professional help is sourced from burkert to setup the flowmeter and get it working.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;'''Piping'''&amp;lt;br/&amp;gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;* Several random leaks were fixed. Most of these are related to hardening and brittle O-rings.&amp;#160; The possibility of acid resistant seals should be investigated.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;* The acid feed pipe after the rotameter was rerouted directly into the tank.&amp;#160; A handvalve was added before the rotameter to throttle the flow.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;* The piping system to load water into the tanks was changed completely.&amp;#160; Water can now be added directly into any of the four feed drums to make the feed solutions.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;* The waste drum setup was changed to accomodate two drums.&amp;#160; It is recommended that a y-fitting be inserted to the waste pipe so that both tanks fill up at the same time.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;'''Systems'''&amp;lt;br/&amp;gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;* The pH rig computer was formatted and reinstalled with Windows 2003 Server&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>137.215.116.248</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=480&amp;oldid=prev</id>
		<title>AndreC at 17:33, 10 November 2009</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=480&amp;oldid=prev"/>
				<updated>2009-11-10T17:33:40Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class='diff diff-contentalign-left'&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;tr style='vertical-align: top;'&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;Revision as of 17:33, 10 November 2009&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;L15&quot; &gt;Line 15:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 15:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* PH probe connected to pH transmitter 2 has stopped working. Replaced with working probe. Short wire on new probed forced the cover of pH transmitter 2 to be turned around so as to reach top tank (see image).&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* PH probe connected to pH transmitter 2 has stopped working. Replaced with working probe. Short wire on new probed forced the cover of pH transmitter 2 to be turned around so as to reach top tank (see image).&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Pump 2 (base pump) was delivering a very low flow when compared to the identical pump 1 (acid pump). The impeller of pump 2 was most likely damaged due to bad decommissioning of the rig. The two pumps were switched so that the 'slower' pump operates on the line which has no control valves.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Pump 2 (base pump) was delivering a very low flow when compared to the identical pump 1 (acid pump). The impeller of pump 2 was most likely damaged due to bad decommissioning of the rig. The two pumps were switched so that the 'slower' pump operates on the line which has no control valves.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;[[File:Pmc02ph_tankstand_before.JPG|150px|thumb|Old feed tank stand]] [[File:Pmc02ph_tankstand_after.JPG|150px|thumb|New feed tank stand]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''Piping'''&amp;lt;br/&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''Piping'''&amp;lt;br/&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Numerous leaks were fixed and connections made where piping has been scavenged off the rig.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Numerous leaks were fixed and connections made where piping has been scavenged off the rig.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''Structural'''&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''Structural'''&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:Pmc02ph_tankstand_before.JPG|150px|thumb|Old feed tank stand]] [[File:Pmc02ph_tankstand_after.JPG|150px|thumb|New feed tank stand]]&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Stands for feed tanks (currently dustbins) were found to not give sufficient support when tanks are full. Constructed new feed tank stand.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Stands for feed tanks (currently dustbins) were found to not give sufficient support when tanks are full. Constructed new feed tank stand.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Fitting of stirrers to tanks found to be flimsy. Versatility of stands (moving them around) outweighed effort to construct new stands. Left as is, but sturdier stands are recommended.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Fitting of stirrers to tanks found to be flimsy. Versatility of stands (moving them around) outweighed effort to construct new stands. Left as is, but sturdier stands are recommended.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Rerouted pipe connecting CV001 and FE001 - cut away some of the metal structure to remove strain from pipe.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Rerouted pipe connecting CV001 and FE001 - cut away some of the metal structure to remove strain from pipe.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>AndreC</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=479&amp;oldid=prev</id>
		<title>AndreC: Pumps</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=479&amp;oldid=prev"/>
				<updated>2009-11-10T17:32:48Z</updated>
		
		<summary type="html">&lt;p&gt;Pumps&lt;/p&gt;
&lt;table class='diff diff-contentalign-left'&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;tr style='vertical-align: top;'&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan='2' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;Revision as of 17:32, 10 November 2009&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;L14&quot; &gt;Line 14:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 14:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Re-fitted pH transmitter 1 and connected a new pH probe.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Re-fitted pH transmitter 1 and connected a new pH probe.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* PH probe connected to pH transmitter 2 has stopped working. Replaced with working probe. Short wire on new probed forced the cover of pH transmitter 2 to be turned around so as to reach top tank (see image).&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* PH probe connected to pH transmitter 2 has stopped working. Replaced with working probe. Short wire on new probed forced the cover of pH transmitter 2 to be turned around so as to reach top tank (see image).&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;* Pump 2 (base pump) was delivering a very low flow when compared to the identical pump 1 (acid pump). The impeller of pump 2 was most likely damaged due to bad decommissioning of the rig. The two pumps were switched so that the 'slower' pump operates on the line which has no control valves.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''Piping'''&amp;lt;br/&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''Piping'''&amp;lt;br/&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>AndreC</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=477&amp;oldid=prev</id>
		<title>AndreC: Migrated pH rig maintenance to dedicated page</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=PH_Rig_Maintenance&amp;diff=477&amp;oldid=prev"/>
				<updated>2009-11-10T17:03:07Z</updated>
		
		<summary type="html">&lt;p&gt;Migrated pH rig maintenance to dedicated page&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;This page documents the maintenance done as well as changes made to the pH rig. It is important that all changes be noted here as it makes the tracking of scavenged/stolen equipment a little easier.&lt;br /&gt;
== Pre 2009 ==&lt;br /&gt;
Maintenance and changes made to the pH rig before 2009 are not explicitly maintained on the wiki. Consult the project documentation of previous years for said changes.&lt;br /&gt;
== 2009 ==&lt;br /&gt;
'''Wiring/Instrumentation'''&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:Pmc02ph_instruments.JPG|300px|right|thumb|pH rig instruments showing new temp. transmitter housing and turned pH transmitter cover]]&lt;br /&gt;
Wiring of rig found to be in a state of disrepair. An attempt is made to fix all wiring and restore all electronic equipment to a working condition. Fixed equipment/wiring is listed below:&lt;br /&gt;
* I/P transducer for control valve 2 and 1 faulty. Replaced both transducers, reconnected piping and wiring.&lt;br /&gt;
* Control valve 2 - reconnected piping.&lt;br /&gt;
* All the RTDs and temperature transmitters have been removed from the rig (scavenged). Fitted an RTD to each tank and wired to new temperature transmitters.&lt;br /&gt;
* Housing for temperature transmitters made and fitted to rig (see image).&lt;br /&gt;
* Control valve 1 seems to be stuck. Apparently the original valve was removed and replaced by current non-working valve. Valve was opened and oiled and reconnected to new I/P transducer. In working order now.&lt;br /&gt;
* Original Signet flow sensor has been removed from rig. A new Burkert flow sensor was fitted to the inlet of tank 3. Old signal conditioner was removed and its power supply removed from the DB. Cable 006 from the DB was wired to the loop power and a Burkert flow transmitter was installed. Unfortunately, both Burkert flow transmitters (brand new) were faulty and the flow measurement has been abandoned due to time constraints.&lt;br /&gt;
* Re-fitted pH transmitter 1 and connected a new pH probe.&lt;br /&gt;
* PH probe connected to pH transmitter 2 has stopped working. Replaced with working probe. Short wire on new probed forced the cover of pH transmitter 2 to be turned around so as to reach top tank (see image).&lt;br /&gt;
&lt;br /&gt;
'''Piping'''&amp;lt;br/&amp;gt;&lt;br /&gt;
Numerous leaks were fixed and connections made where piping has been scavenged off the rig.&lt;br /&gt;
&lt;br /&gt;
'''Structural'''&lt;br /&gt;
[[File:Pmc02ph_tankstand_before.JPG|150px|thumb|Old feed tank stand]] [[File:Pmc02ph_tankstand_after.JPG|150px|thumb|New feed tank stand]]&lt;br /&gt;
* Stands for feed tanks (currently dustbins) were found to not give sufficient support when tanks are full. Constructed new feed tank stand.&lt;br /&gt;
* Fitting of stirrers to tanks found to be flimsy. Versatility of stands (moving them around) outweighed effort to construct new stands. Left as is, but sturdier stands are recommended.&lt;br /&gt;
* Rerouted pipe connecting CV001 and FE001 - cut away some of the metal structure to remove strain from pipe.&lt;/div&gt;</summary>