<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>http://chemeng.up.ac.za/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Deon+Pretorius</id>
		<title>Chemical Engineering @ UP wiki - User contributions [en]</title>
		<link rel="self" type="application/atom+xml" href="http://chemeng.up.ac.za/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Deon+Pretorius"/>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php/Special:Contributions/Deon_Pretorius"/>
		<updated>2026-05-14T00:25:50Z</updated>
		<subtitle>User contributions</subtitle>
		<generator>MediaWiki 1.25.1</generator>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39257</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39257"/>
				<updated>2018-11-21T07:51:01Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Image:col_pic_1.png|right|200px]]&lt;br /&gt;
==Description==&lt;br /&gt;
[[Image:col_pic_2.png|right|200px]]&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the selected base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
=== 2018: Deon Pretorius, Greg Laycock ===&lt;br /&gt;
'''Set-up''' The DeltaV software was updated from version to 9 and 14. This required the old hardware to be removed and new hardware to be installed.&lt;br /&gt;
&lt;br /&gt;
'''Operator interface''' The original SASOL graphical user interface was removed and a new user interface was designed and implemented.&lt;br /&gt;
&lt;br /&gt;
'''Control valve response tuning''' The control valve responses to set-points were insufficient. The control valve responses were tuned to ensure smooth transition to set-point with no offset or hunting.&lt;br /&gt;
&lt;br /&gt;
'''Maintenance''' The following maintenance was completed on the system:&lt;br /&gt;
* Substantial leak below reflux drum repaired&lt;br /&gt;
* Fouling in reflux line removed&lt;br /&gt;
* Some RDT wiring redone&lt;br /&gt;
* Some flow indicator wiring redone&lt;br /&gt;
* New regulator installed&lt;br /&gt;
* New steam trap installed&lt;br /&gt;
&lt;br /&gt;
'''Base-layer control''' Initial base-layer control implementation. A reasonable base-layer control scheme postulated and added to the operator interface.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-11 is:&lt;br /&gt;
&lt;br /&gt;
'''Name''' Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
'''Company''' [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
'''Tel''' +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
'''Cell''' +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
'''E-mail''' Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
'''Name''' Andre Joubert&lt;br /&gt;
&lt;br /&gt;
'''Company''' [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
'''Cell''' +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
'''E-mail''' Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39256</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39256"/>
				<updated>2018-11-20T08:43:11Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Image:col_pic_1.png|right|200px]]&lt;br /&gt;
==Description==&lt;br /&gt;
[[Image:col_pic_2.png|right|200px]]&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the selected base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
=== Deon Pretorius, Greg Laycock, 2018 ===&lt;br /&gt;
'''Set-up''' The DeltaV software was updated from version to 9 and 14. This required the old hardware to be removed and new hardware to be installed.&lt;br /&gt;
&lt;br /&gt;
'''Operator interface''' The original SASOL graphical user interface was removed and a new user interface was designed and implemented.&lt;br /&gt;
&lt;br /&gt;
'''Control valve response tuning''' The control valve responses to set-points were insufficient. The control valve responses were tuned to ensure smooth transition to set-point with no offset or hunting.&lt;br /&gt;
&lt;br /&gt;
'''Maintenance''' The following maintenance was completed on the system:&lt;br /&gt;
* Substantial leak below reflux drum repaired&lt;br /&gt;
* Fouling in reflux line removed&lt;br /&gt;
* Some RDT wiring redone&lt;br /&gt;
* Some flow indicator wiring redone&lt;br /&gt;
* New regulator installed&lt;br /&gt;
* New steam trap installed&lt;br /&gt;
&lt;br /&gt;
'''Base-layer control''' Initial base-layer control implementation. A reasonable base-layer control scheme postulated and added to the operator interface.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-11 is:&lt;br /&gt;
&lt;br /&gt;
'''Name''' Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
'''Company''' [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
'''Tel''' +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
'''Cell''' +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
'''E-mail''' Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
'''Name''' Andre Joubert&lt;br /&gt;
&lt;br /&gt;
'''Company''' [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
'''Cell''' +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
'''E-mail''' Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39255</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39255"/>
				<updated>2018-11-20T08:39:39Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Image:col_pic_1.png|right|200px]]&lt;br /&gt;
==Description==&lt;br /&gt;
[[Image:col_pic_2.png|right|200px]]&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the selected base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
=== Deon Pretorius, Greg Laycock, 2018 ===&lt;br /&gt;
'''Set-up''' The DeltaV software was updated from version to 9 and 14. This required the old hardware to be removed and new hardware to be installed.&lt;br /&gt;
&lt;br /&gt;
'''Operator interface''' The original SASOL graphical user interface was removed and a new user interface was designed and implemented.&lt;br /&gt;
&lt;br /&gt;
'''Control valve response tuning''' The control valve responses to set-points were insufficient. The control valve responses were tuned to ensure smooth transition to set-point with no offset or hunting.&lt;br /&gt;
&lt;br /&gt;
'''Maintenance''' The following maintenance was completed on the system:&lt;br /&gt;
* Substantial leak below reflux drum repaired&lt;br /&gt;
* Fouling in reflux line removed&lt;br /&gt;
* Some RDT wiring redone&lt;br /&gt;
* Some flow indicator wiring redone&lt;br /&gt;
* New regulator installed&lt;br /&gt;
* New steam trap installed&lt;br /&gt;
&lt;br /&gt;
'''Base-layer control''' Initial base-layer control implementation. A reasonable base-layer control scheme postulated and added to the operator interface.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=File:Col_pic_2.png&amp;diff=39254</id>
		<title>File:Col pic 2.png</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=File:Col_pic_2.png&amp;diff=39254"/>
				<updated>2018-11-20T08:36:41Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39253</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39253"/>
				<updated>2018-11-20T08:36:05Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Image:col_pic_1.png|right|200px]]&lt;br /&gt;
==Description==&lt;br /&gt;
[[Image:col_pic_2.png|right|200px]]&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the selected base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
=== Deon Pretorius, Greg Laycock, 2018 ===&lt;br /&gt;
'''Set-up''' The DeltaV software was updated from version to 9 and 14. This required the old hardware to be removed and new hardware to be installed.&lt;br /&gt;
&lt;br /&gt;
'''Operator interface''' The original SASOL graphical user interface was removed and a new user interface was designed and implemented.&lt;br /&gt;
&lt;br /&gt;
'''Control valve response tuning''' The control valve responses to set-points were insufficient. The control valve responses were tuned to ensure smooth transition to set-point with no offset or hunting.&lt;br /&gt;
&lt;br /&gt;
'''Maintenance''' The following maintenance was completed on the system:&lt;br /&gt;
* Substantial leak below reflux drum repaired&lt;br /&gt;
* Fouling in reflux line removed&lt;br /&gt;
* Some RDT wiring redone&lt;br /&gt;
* Some flow indicator wiring redone&lt;br /&gt;
* New regulator installed&lt;br /&gt;
* New steam trap installed&lt;br /&gt;
&lt;br /&gt;
'''Base-layer control''' Initial base-layer control implementation. A reasonable base-layer control scheme postulated and added to the operator interface.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39251</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39251"/>
				<updated>2018-11-20T08:29:01Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Image:col_pic_1.png|right|300px]]&lt;br /&gt;
==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the selected base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
=== Deon Pretorius, Greg Laycock, 2018 ===&lt;br /&gt;
'''Set-up''' The DeltaV software was updated from version to 9 and 14. This required the old hardware to be removed and new hardware to be installed.&lt;br /&gt;
&lt;br /&gt;
'''Operator interface''' The original SASOL graphical user interface was removed and a new user interface was designed and implemented.&lt;br /&gt;
&lt;br /&gt;
'''Control valve response tuning''' The control valve responses to set-points were insufficient. The control valve responses were tuned to ensure smooth transition to set-point with no offset or hunting.&lt;br /&gt;
&lt;br /&gt;
'''Maintenance''' The following maintenance was completed on the system:&lt;br /&gt;
* Substantial leak below reflux drum repaired&lt;br /&gt;
* Fouling in reflux line removed&lt;br /&gt;
* Some RDT wiring redone&lt;br /&gt;
* Some flow indicator wiring redone&lt;br /&gt;
* New regulator installed&lt;br /&gt;
* New steam trap installed&lt;br /&gt;
&lt;br /&gt;
'''Base-layer control''' Initial base-layer control implementation. A reasonable base-layer control scheme postulated and added to the operator interface.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39250</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39250"/>
				<updated>2018-11-20T08:28:45Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Image:col_pic_1.png|right|700px]]&lt;br /&gt;
==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the selected base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
=== Deon Pretorius, Greg Laycock, 2018 ===&lt;br /&gt;
'''Set-up''' The DeltaV software was updated from version to 9 and 14. This required the old hardware to be removed and new hardware to be installed.&lt;br /&gt;
&lt;br /&gt;
'''Operator interface''' The original SASOL graphical user interface was removed and a new user interface was designed and implemented.&lt;br /&gt;
&lt;br /&gt;
'''Control valve response tuning''' The control valve responses to set-points were insufficient. The control valve responses were tuned to ensure smooth transition to set-point with no offset or hunting.&lt;br /&gt;
&lt;br /&gt;
'''Maintenance''' The following maintenance was completed on the system:&lt;br /&gt;
* Substantial leak below reflux drum repaired&lt;br /&gt;
* Fouling in reflux line removed&lt;br /&gt;
* Some RDT wiring redone&lt;br /&gt;
* Some flow indicator wiring redone&lt;br /&gt;
* New regulator installed&lt;br /&gt;
* New steam trap installed&lt;br /&gt;
&lt;br /&gt;
'''Base-layer control''' Initial base-layer control implementation. A reasonable base-layer control scheme postulated and added to the operator interface.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=File:Col_pic_1.png&amp;diff=39249</id>
		<title>File:Col pic 1.png</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=File:Col_pic_1.png&amp;diff=39249"/>
				<updated>2018-11-20T08:28:08Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39248</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39248"/>
				<updated>2018-11-20T08:27:11Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Image:col_pic_1.jpg|right|700px]]&lt;br /&gt;
==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the selected base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
=== Deon Pretorius, Greg Laycock, 2018 ===&lt;br /&gt;
'''Set-up''' The DeltaV software was updated from version to 9 and 14. This required the old hardware to be removed and new hardware to be installed.&lt;br /&gt;
&lt;br /&gt;
'''Operator interface''' The original SASOL graphical user interface was removed and a new user interface was designed and implemented.&lt;br /&gt;
&lt;br /&gt;
'''Control valve response tuning''' The control valve responses to set-points were insufficient. The control valve responses were tuned to ensure smooth transition to set-point with no offset or hunting.&lt;br /&gt;
&lt;br /&gt;
'''Maintenance''' The following maintenance was completed on the system:&lt;br /&gt;
* Substantial leak below reflux drum repaired&lt;br /&gt;
* Fouling in reflux line removed&lt;br /&gt;
* Some RDT wiring redone&lt;br /&gt;
* Some flow indicator wiring redone&lt;br /&gt;
* New regulator installed&lt;br /&gt;
* New steam trap installed&lt;br /&gt;
&lt;br /&gt;
'''Base-layer control''' Initial base-layer control implementation. A reasonable base-layer control scheme postulated and added to the operator interface.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39245</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39245"/>
				<updated>2018-11-20T08:17:30Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Control system */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the selected base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
=== Deon Pretorius, Greg Laycock, 2018 ===&lt;br /&gt;
'''Set-up''' The DeltaV software was updated from version to 9 and 14. This required the old hardware to be removed and new hardware to be installed.&lt;br /&gt;
&lt;br /&gt;
'''Operator interface''' The original SASOL graphical user interface was removed and a new user interface was designed and implemented.&lt;br /&gt;
&lt;br /&gt;
'''Control valve response tuning''' The control valve responses to set-points were insufficient. The control valve responses were tuned to ensure smooth transition to set-point with no offset or hunting.&lt;br /&gt;
&lt;br /&gt;
'''Maintenance''' The following maintenance was completed on the system:&lt;br /&gt;
* Substantial leak below reflux drum repaired&lt;br /&gt;
* Fouling in reflux line removed&lt;br /&gt;
* Some RDT wiring redone&lt;br /&gt;
* Some flow indicator wiring redone&lt;br /&gt;
* New regulator installed&lt;br /&gt;
* New steam trap installed&lt;br /&gt;
&lt;br /&gt;
'''Base-layer control''' Initial base-layer control implementation. A reasonable base-layer control scheme postulated and added to the operator interface.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39244</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39244"/>
				<updated>2018-11-17T12:15:32Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: Deon and Greg project history added&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
=== Deon Pretorius, Greg Laycock, 2018 ===&lt;br /&gt;
'''Set-up''' The DeltaV software was updated from version to 9 and 14. This required the old hardware to be removed and new hardware to be installed.&lt;br /&gt;
&lt;br /&gt;
'''Operator interface''' The original SASOL graphical user interface was removed and a new user interface was designed and implemented.&lt;br /&gt;
&lt;br /&gt;
'''Control valve response tuning''' The control valve responses to set-points were insufficient. The control valve responses were tuned to ensure smooth transition to set-point with no offset or hunting.&lt;br /&gt;
&lt;br /&gt;
'''Maintenance''' The following maintenance was completed on the system:&lt;br /&gt;
* Substantial leak below reflux drum repaired&lt;br /&gt;
* Fouling in reflux line removed&lt;br /&gt;
* Some RDT wiring redone&lt;br /&gt;
* Some flow indicator wiring redone&lt;br /&gt;
* New regulator installed&lt;br /&gt;
* New steam trap installed&lt;br /&gt;
&lt;br /&gt;
'''Base-layer control''' Initial base-layer control implementation. A reasonable base-layer control scheme postulated and added to the operator interface.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39243</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39243"/>
				<updated>2018-11-17T11:41:02Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Recent projects==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39242</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39242"/>
				<updated>2018-11-17T11:39:32Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Diagram */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39241</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39241"/>
				<updated>2018-11-17T11:39:11Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Operator interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|center|1000px]]&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39240</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39240"/>
				<updated>2018-11-17T11:35:24Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Operator interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|1050px|Image: 1000 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39239</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39239"/>
				<updated>2018-11-17T11:34:48Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Operator interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|1050px|Image: 1050 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39238</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39238"/>
				<updated>2018-11-17T11:34:26Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Operator interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|1100px|Image: 1100 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39237</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39237"/>
				<updated>2018-11-17T11:33:04Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Operator interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|1000px|Image: 1000 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39236</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39236"/>
				<updated>2018-11-17T11:31:51Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Operator interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png]]&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=File:Gui.png&amp;diff=39235</id>
		<title>File:Gui.png</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=File:Gui.png&amp;diff=39235"/>
				<updated>2018-11-17T11:30:46Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39234</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39234"/>
				<updated>2018-11-17T11:30:21Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Operator interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.png|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39233</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39233"/>
				<updated>2018-11-17T11:29:05Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Operator interface==&lt;br /&gt;
[[Image:gui.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39232</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39232"/>
				<updated>2018-11-17T11:27:38Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Control system */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The designed operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39231</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39231"/>
				<updated>2018-11-17T11:26:38Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Control system */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Emerson DeltaV v.14 software. The computer in use has specifications according to use of the software. The operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39230</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39230"/>
				<updated>2018-11-17T11:25:55Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Control system */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the DeltaV v.14 software. The computer in use has specifications according to use of the software. The operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control.&lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39229</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39229"/>
				<updated>2018-11-17T11:24:51Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Control system==&lt;br /&gt;
The column is currently controlled making use of the Delta V 14 software. The computer in use has specifications according to use of the software The operator interface is shown below. Most of the control loops can be run either in manual or auto using the postulated base-layer control scheme. No APC is currently being employed for process control. &lt;br /&gt;
&lt;br /&gt;
==Contact persons==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39228</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39228"/>
				<updated>2018-11-17T11:17:40Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Help documentation */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39227</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39227"/>
				<updated>2018-11-17T11:17:10Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Description */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being recycled and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and how to use it click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39226</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39226"/>
				<updated>2018-11-17T11:16:43Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Help documentation */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
For help on the Delta V system and how to use it click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39225</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39225"/>
				<updated>2018-11-17T11:16:11Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Documentation on previous projects */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Previous project documentation== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39224</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39224"/>
				<updated>2018-11-17T11:15:18Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Description */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. This is a closed system with the top product and bottom product being added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39223</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39223"/>
				<updated>2018-11-17T11:13:55Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Description */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column. The distillation column is a closed system with the top product and bottom product being remixed and added to the feed mixing tank.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39222</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39222"/>
				<updated>2018-11-17T11:12:18Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Diagram */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg|700px|Image: 700 pixels]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=File:Column_diagram.jpg&amp;diff=39221</id>
		<title>File:Column diagram.jpg</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=File:Column_diagram.jpg&amp;diff=39221"/>
				<updated>2018-11-17T11:10:18Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39220</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39220"/>
				<updated>2018-11-17T11:09:48Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column.&lt;br /&gt;
&lt;br /&gt;
==Diagram==&lt;br /&gt;
[[Image:column_diagram.jpg]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39219</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39219"/>
				<updated>2018-11-17T11:01:28Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column.&lt;br /&gt;
&lt;br /&gt;
[[File:column_diagram.png]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=File:Column_diagram.png&amp;diff=39218</id>
		<title>File:Column diagram.png</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=File:Column_diagram.png&amp;diff=39218"/>
				<updated>2018-11-17T11:00:21Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39217</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39217"/>
				<updated>2018-11-17T10:59:13Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column.&lt;br /&gt;
&lt;br /&gt;
[[File:column_pic.png]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=File:Column_pic.pdf&amp;diff=39216</id>
		<title>File:Column pic.pdf</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=File:Column_pic.pdf&amp;diff=39216"/>
				<updated>2018-11-17T10:54:49Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39215</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39215"/>
				<updated>2018-11-17T10:54:27Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column.&lt;br /&gt;
&lt;br /&gt;
[[File:column_pic.pdf]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39214</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39214"/>
				<updated>2018-11-17T10:47:05Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Description */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays for each stage. Each stage is fitted with an RDT (resistance temperature detector) temperature measurement device. Column instrumentation include various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column.&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39213</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39213"/>
				<updated>2018-11-17T10:41:22Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays. Each stage is fitted with an RDT (resistance temperature detector) temperature&lt;br /&gt;
measurement device. Column instrumentation also includes various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column.&lt;br /&gt;
[[File:Example.jpg]]&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39212</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39212"/>
				<updated>2018-11-17T10:40:26Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Description */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the main function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stage. The column makes use of donut trays. Each stage is fitted with an RDT (resistance temperature detector) temperature&lt;br /&gt;
measurement device. Column instrumentation also includes various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column.&lt;br /&gt;
&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39211</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39211"/>
				<updated>2018-11-17T10:08:38Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Contact people */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the primary function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stages. The  Each plate is fitted with an RDT (resistance temperature detector) temperature&lt;br /&gt;
measurement device. Column instrumentation also includes various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column.&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: [https://www.sasol.com/ SASOL]&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39210</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39210"/>
				<updated>2018-11-17T10:07:47Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: Started with column description&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Description==&lt;br /&gt;
The glass distillation column was a donation made by Exxon Mobil in 1978. It is a standard glass distillation column with the primary function of distilling ethanol/water mixtures. The column has 10 stages, custom made to include sample points on&lt;br /&gt;
each stages. The  Each plate is fitted with an RDT (resistance temperature detector) temperature&lt;br /&gt;
measurement device. Column instrumentation also includes various Coriolis mass flow meters and refractive index analyzers. Feed plate 3 and feed plate 6 can be used to feed to the column.&lt;br /&gt;
==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: [http://www.aveng-acs.com/ link Avenge ACS]&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: SASOL (https://www.sasol.com/)&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39209</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39209"/>
				<updated>2018-11-17T08:41:04Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Contact people */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
Name: Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Company: Avenge ACS (http://www.aveng-acs.com/)&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cell: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
Name: Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Company: SASOL (https://www.sasol.com/)&lt;br /&gt;
&lt;br /&gt;
Cell : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39208</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39208"/>
				<updated>2018-11-17T08:37:37Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Contact people */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
(Avenge ACS)&lt;br /&gt;
&lt;br /&gt;
Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cel: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
(SASOL (https://www.sasol.com/))&lt;br /&gt;
&lt;br /&gt;
Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Cel : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=SASOL&amp;diff=39207</id>
		<title>SASOL</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=SASOL&amp;diff=39207"/>
				<updated>2018-11-17T08:34:28Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: Created page with &amp;quot;https://www.sasol.com/&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;https://www.sasol.com/&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39206</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39206"/>
				<updated>2018-11-17T08:33:57Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Contact people */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
(Avenge ACS)&lt;br /&gt;
&lt;br /&gt;
Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cel: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
([[SASOL]])&lt;br /&gt;
&lt;br /&gt;
Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Cel : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>
		<author><name>Deon Pretorius</name></author>	</entry>

	<entry>
		<id>http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39205</id>
		<title>Big distillation column</title>
		<link rel="alternate" type="text/html" href="http://chemeng.up.ac.za/wiki/index.php?title=Big_distillation_column&amp;diff=39205"/>
				<updated>2018-11-17T08:32:38Z</updated>
		
		<summary type="html">&lt;p&gt;Deon Pretorius: /* Contact people */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Contact people==&lt;br /&gt;
&lt;br /&gt;
For help with the Emerson control system ([[Delta V]]) the contact person as of 2018-12 is:&lt;br /&gt;
&lt;br /&gt;
(Avenge ACS)&lt;br /&gt;
&lt;br /&gt;
Daniela Straulino&lt;br /&gt;
&lt;br /&gt;
Tel: +27-11-249-6700 &lt;br /&gt;
&lt;br /&gt;
Cel: +27-82-407-8590&lt;br /&gt;
&lt;br /&gt;
E-mail: Daniela.Straulino@avenggroup.com&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For other general maintenance concerns and instrumentation problems the contact person is: &lt;br /&gt;
&lt;br /&gt;
(SASOL)&lt;br /&gt;
&lt;br /&gt;
Andre Joubert&lt;br /&gt;
&lt;br /&gt;
Cel : +27-82-905-0090&lt;br /&gt;
&lt;br /&gt;
E-mail : Andre.Joubert@sasol.com&lt;br /&gt;
&lt;br /&gt;
==Documentation on previous projects== &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Documentation on past projects that were done on the distillation column can be found  [http://ragnarok.up.ac.za/Rigs/BigDistillationColumn/ here].&lt;br /&gt;
&lt;br /&gt;
==Help documentation== &lt;br /&gt;
&lt;br /&gt;
Help on the Delta V system and how to use click [http://www.chem.mtu.edu/chem_eng/current/new_courses/CM4120/2009/Getting%20Started.pdf  here].&lt;/div&gt;</summary>